DCP Fire Extinguisher in Mumbai

Two red cartridge-type dry powder fire extinguishers with plunger caps beside a larger powder unit on a wheeled trolley

Cease Fire & Electrical Services LLP supplies ISI-marked DCP (dry chemical powder) fire extinguishers in Mumbai from our own CEASE FIRE range, from 1 kg portable units to 150 kg trolley units. A DCP extinguisher uses BC powder to knock down fires in flammable liquids and gases, so it is widely used in fuel stores, workshops, factories, petrol and gas handling areas. We supply, install, refill and service them under AMC.

CEASE FIRE DCP extinguishers

ModelCapacityOperationDischarge timeJet range
DP01CTG1 kgCO2 cartridge8–10 sec2 m
DP02CTG2 kgCO2 cartridge8–10 sec2 m
DP05CTG5 kgCO2 cartridge15–20 sec4 m
DP10CTG10 kgCO2 cartridge23–30 sec6 m
DP25CTG25 kg trolleyCO2 cartridge25–30 sec6 m
DP25Co225 kg trolleyCO2 cylinder with regulator valve25–30 sec6 m
DP50Co250 kg trolleyCO2 cylinder with regulator valve40–50 sec8 m
DP75Co275 kg trolleyCO2 cylinder with regulator valve50–60 sec10 m
DP150Co2150 kg trolleyCO2 cylinder with regulator valveAsk usAsk us

The portable cartridge units are refillable at site, with a brass forged cap and a weather-resistant epoxy polyester powder coating. They work from −20 °C to +55 °C. The powder used in CEASE FIRE extinguishers does not conduct electricity.

Where DCP extinguishers are used

  • Fuel, oil and solvent stores
  • Petrol pumps, gas banks and LPG areas
  • Workshops, garages and DG rooms
  • Factories, warehouses and loading bays (trolley units)
  • Chemical plants and industrial yards
  • For general areas with paper, wood and fabric, an ABC extinguisher is the better choice, because BC powder is not rated for Class A fires.

Standards

Our DCP extinguishers carry the BIS ISI mark. Portable units are designed to IS 15683.

Supply, installation and servicing

We recommend portable and trolley units for each risk area, place them with signage, and keep them ready with inspection, refilling and hydro-testing, as a one-time service or under AMC.

Engineer crouching beside a large red wheeled trolley fire extinguisher in a factory workshop, checking it against a clipboard, a portable extinguisher on the column behind

Why choose Cease Fire

  • Our own ISI-marked range

    CEASE FIRE DCP extinguishers from 1 kg to 150 kg trolley units.

  • Refillable at site

    Cartridge-type units can be recharged on your premises.

  • Industrial experience since 1992

    Fire protection for clients including BPCL, HPCL and JSW Steel.

Request a quote

Tell us the sizes and quantities you need, or the areas you want to protect. We will send a quote or arrange a site visit.

Frequently asked questions

What is a DCP fire extinguisher?

It is a dry chemical powder extinguisher filled with BC powder (sodium bicarbonate based). It puts out fires in flammable liquids and gases by smothering the flames and stopping the chemical reaction.

What is the difference between ABC and DCP fire extinguishers?

Both use dry powder. An ABC extinguisher uses MAP powder and also works on Class A fires in wood, paper and cloth, while a DCP (BC) extinguisher is meant for flammable liquid and gas fires.

Can a DCP extinguisher be used on electrical fires?

The powder does not conduct electricity, so it can be used on electrical fires. It leaves a residue, so CO2 or clean agent is usually preferred for electronics.

What is a cartridge-type fire extinguisher?

The propellant is kept in a separate CO2 cartridge and only pressurises the body when the extinguisher is operated. This makes the unit easy to refill on site.

When do you need a DCP trolley extinguisher?

Trolley units of 25 to 150 kg are used in large fuel, chemical and industrial areas where a bigger quantity of powder and a longer jet are needed.

Do you refill DCP fire extinguishers?

Yes. We refill DCP extinguishers, replace cartridges and arrange hydro-testing, as a one-time service or under AMC.

Is a DCP extinguisher suitable for a petrol fire?

Yes. A DCP (BC) extinguisher is meant for flammable liquid and gas fires such as petrol, diesel and solvents. Larger fuel areas usually also need a trolley unit.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.

Call +91 9920676281