Engineer testing a wall-mounted fire alarm control panel beside a manual call point

Fire Safety Standards, Licences and Certifications

Cease Fire & Electrical Services LLP holds a current Maharashtra Fire Services Licensed Agency licence (Class B and Class D) and a current Fire and Life Safety Auditor licence. Every credential on this page is shown with its holder, issuing authority, number, scope and validity, so you can verify it before you appoint us.

Current credential snapshot

  1. Maharashtra Fire Services Licensed Agency

    Cease Fire & Electrical Services LLPClass B: Fire Fighting and Sprinkler System. Class D: Detection and Fire Suppression System

    MFS/LA/RF-93/RD-95Current, 31 January 2026 to 30 January 2028

  2. Fire and Life Safety Auditor Licence

    Cease Fire & Electrical Services LLPEvaluation of fire-prevention and life-safety measures in buildings, Maharashtra

    MF&ES/F&LSA/30052026/011Current, 30 May 2026 to 29 May 2028

  3. Maharashtra Electrical Contractor Licence

    Cease Fire & Electrical Services (sole proprietorship)Electrical contracting work in Maharashtra

    Licence No. 17545First issued 28 April 2003; renewed 28 April 2025, valid to 27 April 2028

  4. CPWD Enlistment, Buildings & Roads, Class III

    Cease Fire & Electrical Services (sole proprietorship)Tendering limit ₹4 crore

    59(634)/SDG(Mumbai)/Class-III/2022Valid to 30 May 2028

  5. Udyam Registration

    M/S Cease Fire & Electrical Services LLPMSME enterprise registration, Micro (2025-26)

    UDYAM-MH-18-0230071Registered 3 April 2023

Maharashtra Licensed Agency for fire protection work

Yes, Cease Fire is licensed for fire protection work in Maharashtra. Our Licensed Agency licence, issued by the Directorate of Maharashtra Fire & Emergency Services, covers two classes.

Holder
Cease Fire & Electrical Services LLP
Issuing authority
Directorate of Maharashtra Fire & Emergency Services, Government of Maharashtra
Licence number
MFS/LA/RF-93/RD-95
Class B
Fire Fighting and Sprinkler System
Class D
Detection and Fire Suppression System
Validity
31 January 2026 to 30 January 2028

When reviewing a proposal, compare your project scope with these two classes. Product approvals, design basis and local-authority requirements are checked separately for each project. See our Project Services.

Licensed Agency and the Maharashtra ACMS requirement

Under the Maharashtra Fire Prevention and Life Safety Measures (Amendment) Rules, notified on 12 June 2025, buildings covered by the rules need an Automated Continuous Monitoring System (ACMS) for their fire systems. A licensed agency certifies the system on Form A-1, and the building owner submits a periodic Form B-1 certificate twice a year, in January and July.

Cease Fire is a Licensed Agency and supplies its own FireSense IoT panel for ACMS. The monitoring data is logged at one-minute intervals, with an SMS alert if no data is received for 15 minutes, and the gateway runs on a UPS backup of seven hours. The fire brigade, not the agency, issues any NOC. Whether your building is covered, and from when, depends on its category and the rules in force, so we confirm this at the start of each project. See Fire IoT Monitoring System and our ACMS Form A-1 and B-1 guide.

Discuss ACMS Requirements

Licensed Fire and Life Safety Auditor in Maharashtra

Yes, Cease Fire is a licensed Fire and Life Safety Auditor, licensed by the same Directorate to evaluate whether a building's fire-fighting systems are in good repair and efficient working condition.

Holder
Cease Fire & Electrical Services LLP
Issuing authority
Directorate of Maharashtra Fire & Emergency Services, Government of Maharashtra
Licence number
MF&ES/F&LSA/30052026/011
Scope
Evaluation of fire-prevention and life-safety measures in buildings or parts of buildings
Validity
30 May 2026 to 29 May 2028

The audit method, coverage, testing and report are agreed for each appointment. See our Fire Safety Audit services.

Electrical, government contractor and MSME credentials

These three records answer different procurement questions, so we list them separately.

  • Electrical licence

    Maharashtra Electrical Contractor Licence

    Licence No. 17545

    Licence No. 17545 authorises electrical contracting work within Maharashtra. First issued on 28 April 2003, it was last renewed on 28 April 2025 and is valid to 27 April 2028. The licence is held by Cease Fire & Electrical Services, the sole proprietorship. See Electrical Audit services.

  • Government enlistment

    CPWD Enlistment, Buildings & Roads, Class III

    59(634)/SDG(Mumbai)/Class-III/2022

    The Central Public Works Department enlistment (order dated 31 May 2023) lists Cease Fire & Electrical Services, a sole proprietorship, in the Buildings & Roads category, Class III, with a tendering limit of ₹4 crore. It is valid to 30 May 2028. This enlistment is held by the proprietorship, not by the LLP.

  • MSME registration

    Udyam Registration

    UDYAM-MH-18-0230071

    M/S Cease Fire & Electrical Services LLP is registered as a Micro enterprise under Udyam number UDYAM-MH-18-0230071, registered 3 April 2023. Udyam is an MSME business registration, not a technical approval.

Empanelment and recognition

  • Ministry of MSME

Cease Fire is empanelled with the Bureau of Energy Efficiency (BEE), the National Small Industries Corporation (NSIC), the National Safety Council and the Ministry of MSME. Our audit team includes BEE-certified Energy Auditors and Energy Managers, IFE and OHSAS lead auditors, British Safety Council five-star auditors, NSIC safety auditors, Class-I electrical licence holders and Level 1 certified thermographers, and our audit instruments are calibrated every year at NABL-accredited labs. In 2002, Cease Fire received the Rashtriya Nirman Ratna Award for Best Government Contractor.

MEP qualification

Our Director, Mr. Abhishek Anant Bedarkar, holds a Post Graduate Diploma in Mechanical, Electrical and Plumbing from Suvidya Institute of Technology (4 September 2018). It supports our coordinated fire, electrical and plumbing design work. This is a personal qualification, not a company accreditation.

See MEP Consultation and Design.

Standards applied by system and project

The standards that apply depend on your building, occupancy, authority, system, products and consultant specification. We review each agreed scope against the relevant National Building Code provisions, Indian Standards, NFPA references and manufacturer documentation, and confirm the current edition during technical review. Referencing a standard does not make a company "NFPA certified" or "NBC certified", and we don't claim either.

  1. Statutory fire and life safety

    Maharashtra fire-prevention and life-safety law and NBC requirements in force

    Occupancy, authority, appointment type, statutory deliverable, licence scope

  2. Building fire safety

    National Building Code of India, Part 4, where applicable

    Edition, local adoption, occupancy class, approved drawings

  3. Hydrant, pump and sprinkler systems

    NBC and project requirements; NFPA 13 for sprinklers where specified

    Hazard class, water supply, hydraulic calculation, equipment submittals

  4. Hydrant fittings and hose

    IS 5290 (hydrant valves), IS 636 (Type A RRL delivery hose), IS 903 (branch pipes and nozzles), IS 884 (first-aid hose reels)

    Exact product, size, BIS marking and test evidence for the model supplied

  5. Fire detection and alarm

    IS 2189 and NFPA 72 where specified

    System type, zoning or loops, cause-and-effect, device models, test records

  6. Portable fire extinguishers

    Indian Standards including IS 15683 (portable extinguishers, performance and construction; the 2018 edition applies to our clean agent and kitchen extinguisher range), IS 2190, IS 2171, IS 13849, IS 10658, IS 11833 and IS 2189

    Extinguisher type, agent, model, BIS evidence, maintenance

  7. Gas and clean agent suppression

    NFPA 2001 for clean agent systems, such as FK-5-1-12 kits; manufacturer requirements for the selected agent

    Agent, design basis, enclosure, hardware approval, calculations, commissioning

  8. Kitchen fire suppression

    UL 300 test standard for restaurant wet chemical systems, where the manufacturer's documents support the exact model

    Model, nozzle layout, appliance coverage, fusible links, commissioning

  9. Fire IoT monitoring (ACMS)

    Maharashtra Fire Prevention and Life Safety Measures (Amendment) Rules, 12 June 2025, Forms A-1 and B-1

    Building category, sensors covered, data and alert settings, certificate holder

  10. Electrical work

    Electrical rules, the Maharashtra electrical licence scope and project specification

    Holder, permitted work, drawings, test records, sign-off

  11. Product approvals

    UL, FM, EN, VdS, LPCB, BIS/ISI, BS and CE, where the exact model's documents support it

    Manufacturer, model, certificate number, category, limits, status

  • Hydrant, pump and sprinkler systems

    Water-based systems need a design basis that identifies the protected risk, water supply, hazard class, network, calculations and equipment. NFPA 13 is used for sprinklers where the specification or authority requires it. For the fittings, hydrant valves are checked against IS 5290, RRL delivery hose against IS 636, branch pipes against IS 903 and hose reels against IS 884.

  • Fire detection and alarm systems

    Alarm systems may reference IS 2189 and NFPA 72, plus the approved cause-and-effect and manufacturer compatibility data. Verify panel type, zoning, device models, integration, power supply and test records.

  • Fire suppression and extinguishers

    CO2, wet chemical, FK-5-1-12 (Novec 1230), HFC-227ea (FM-200) and inert gas systems each need their own design, hardware and commissioning evidence. Clean agent kits, such as Honeywell ECS FK-5-1-12 systems, are designed to NFPA 2001. Kitchen systems such as the Lehavot WCK are tested to UL 300 according to the manufacturer's documents. Clean agent and kitchen extinguishers from INTIME are made to IS 15683:2018. One approval can't be carried across different systems or models.

Product and model approvals are verified per requirement

UL Listed, FM Approved, EN, VdS, LPCB, BIS/ISI, BS and CE marks apply to exact products and models, not to a company or a whole product category.

When your specification needs an approval, we check it at manufacturer-and-model level before ordering, and again if a substitution is proposed.

  • Manufacturer and full model or catalogue reference
  • Listing, file or certificate number
  • Product category and permitted application
  • Limitations, ratings and compatible components
  • Current status and document date
  • Substitution and technical-review record, where applicable

From approved requirement to documented handover

We turn standards into project decisions and records. The exact steps depend on your system, facility and specification.

  1. Identify requirements

    facility, occupancy, hazard, system, authority and consultant specification.

  2. Review drawings and scope

    design basis, interfaces, quantities, responsibilities and exclusions.

  3. Select documented materials

    match each manufacturer and model to the requirement and its approval evidence.

  4. Submit technical evidence

    drawings, datasheets, calculations, certificates and listings for review.

  5. Inspect installation

    check installed work against the approved scope and record observations.

  6. Test and commission

    functional, performance and interface checks, with results and corrective actions.

  7. Record observations

    inspection, test and commissioning records with clear status and next action.

  8. Train and hand over

    operating guidance, records and drawings for your facility team.

  9. Maintain records under AMC

    planned inspections, maintenance and service reports. See AMC Services.

Review our credential documents

Each document below is a redacted copy (signatures, tax IDs and personal details removed), with its key facts shown in text beside the link.

Maharashtra Licensed Agency licence
Cease Fire & Electrical Services LLP; MFS/LA/RF-93/RD-95; Class B and Class D; valid 31 January 2026 to 30 January 2028
Fire and Life Safety Auditor licence
Cease Fire & Electrical Services LLP; MF&ES/F&LSA/30052026/011; valid 30 May 2026 to 29 May 2028
Maharashtra Electrical Contractor Licence
Cease Fire & Electrical Services; No. 17545; valid to 27 April 2028
CPWD Class III Enlistment Order
Cease Fire & Electrical Services (sole proprietorship); Buildings & Roads Class III; ₹4 crore limit; valid to 30 May 2028
Udyam Registration Certificate
M/S Cease Fire & Electrical Services LLP; UDYAM-MH-18-0230071; registered 3 April 2023
MEP qualification
Abhishek Anant Bedarkar; PG Diploma in MEP; 4 September 2018

Fire protection credential verification checklist

Use these checks for any provider, product or scope, including ours.

  • Confirm the legal name or person shown as the holder.
  • Identify the issuing authority, institution, listing body or manufacturer.
  • Match the licence, order, registration or certificate number.
  • Read the exact class, category or permitted work.
  • Check issue, renewal and expiry dates.
  • Confirm the jurisdiction, location and project applicability.
  • For product approvals, match the exact manufacturer, model and category.
  • For sign-off, identify the responsible named professional.
  • Agree the drawings, calculations, test, commissioning and handover records required.
  • Agree how substitutions, renewals and expiries will be handled.

Discuss your compliance and documentation requirements

Tell us what your project, facility, consultant or procurement team needs to verify. Share the site location, facility type, system, project stage, authority or consultant requirement, any named standard or product approval, and available drawings, BOQ, specification or reports. We'll review the scope and confirm the next step and the evidence you need.

Standards and certifications FAQs

Is Cease Fire licensed for fire protection work in Maharashtra?

Yes. Cease Fire & Electrical Services LLP holds Maharashtra Licensed Agency licence MFS/LA/RF-93/RD-95 for Class B (Fire Fighting and Sprinkler System) and Class D (Detection and Fire Suppression System), valid from 31 January 2026 to 30 January 2028.

What work does the Licensed Agency licence cover?

Class B covers fire fighting and sprinkler systems, and Class D covers detection and fire suppression systems. Design basis, authority requirements and product approvals are verified separately for each project.

Does Cease Fire hold a Fire and Life Safety Auditor licence?

Yes. Licence MF&ES/F&LSA/30052026/011 covers evaluation of fire-prevention and life-safety measures in buildings in Maharashtra, valid from 30 May 2026 to 29 May 2028.

Which fire safety standards does Cease Fire follow?

It depends on the building, occupancy, authority, system and specification. References may include the National Building Code, Indian Standards such as IS 2189, and NFPA standards such as NFPA 13, NFPA 72 and NFPA 2001. The current edition is confirmed during technical review.

What is ACMS and does Cease Fire provide the certificate?

ACMS is the Automated Continuous Monitoring System required for covered buildings under the Maharashtra fire rules amended on 12 June 2025. As a Licensed Agency, Cease Fire certifies the ACMS it provides on Form A-1, and the owner files Form B-1 twice a year.

Are all products supplied by Cease Fire UL Listed or FM Approved?

No. Approvals apply to exact models, not whole categories. Where your project requires UL, FM or another approval, we verify it for the exact manufacturer and model and provide the documents.

Can I view Cease Fire's licence documents?

Yes. Redacted copies of each licence and registration are available on this page, with the key facts in text beside each link. A full credential pack is available on request for tenders.

How do I know the licence details are current?

Each credential shows its validity dates. We review every licence before it expires and update this page after each renewal. You can also verify any licence directly with the issuing authority.

Does the Director's MEP qualification certify the company?

No. The PG Diploma in Mechanical, Electrical and Plumbing belongs to Mr. Abhishek Anant Bedarkar personally. It supports our MEP design capability but is not a company accreditation.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.

Call +91 9920676281