Fire Fighting Valves in Mumbai

Cease Fire & Electrical Services LLP supplies valves for fire fighting pipework in Mumbai: butterfly, gate (sluice), non-return and check valves, ball valves, air release valves, Y strainers, bellows and solenoid valves. Our flanged cast iron and ductile iron valves come in 40 mm to 300 mm sizes, rated PN 1.6, 2.0 and 2.5 MPa. We select, supply and install them as part of hydrant, sprinkler and pump room work.
Valves we supply

Butterfly valve
Quarter-turn isolation on pump headers, risers and ring mains
Range we supplyCast iron body, SG iron or stainless steel disc, EPDM liner; 40 to 300 mm

Gate valve (sluice valve)
Full-bore isolation with low pressure loss
Range we supplyCast iron to IS 14846, and resilient-seated ductile iron; 50 to 300 mm

Non-return valve
Stops water flowing back, for example into a pump that is not running
Range we supplyCast iron swing type (reflux) to IS 5312, dual plate and wafer check valves; 40 to 300 mm

Swing check valve
Non-return protection on smaller screwed lines
Range we supplyBronze, screwed BSP ends; 15 to 100 mm

Air release valve
Lets trapped air out of high points and risers
Range we supplyForged brass, 15 to 25 mm; cast iron kinetic air valve, flanged, 25 to 200 mm

Ball valve
Quarter-turn shut-off on drains, test lines and small branches
Range we supplyForged brass, screwed, 8 to 100 mm; cast iron flanged, 15 to 100 mm

Y strainer
Catches debris before pumps, control valves and pressure reducing valves
Range we supplyCast iron, flanged, stainless steel screen; 25 to 300 mm

Bellows
Absorb vibration and pipe movement at pump connections
Range we supplyOn request

Solenoid valve
Electrically opens or closes a line on a signal from a control panel
Range we supplyOn request
We also supply forged brass pressure reducing valves (DN 15 to 100). Flanged valves are hydrostatically tested at 2.4 MPa on the body and 1.6 MPa on the seat. Looking for hydrant valves or sprinkler alarm and deluge valves? They have their own pages.
Where valves go in a fire system
- Pump room: isolation valves on each pump's suction and delivery, a non-return valve on each delivery, and strainers where the design needs them. See fire pump room.
- Risers and ring mains: isolation valves to shut off sections for maintenance, and air release valves at high points.
- Sprinkler lines: isolation and drain or test valves around each installation valve. See fire sprinklers.
Choosing the right valve
We confirm five things before supply:
- Size to match the pipe and the design flow.
- Pressure rating (PN) above the system's working pressure.
- End connection: flanged (IS 1538 or Class 150), wafer, or screwed BSP.
- Material to suit the water quality and location.
- Specification: some consultants and insurers call for UL listed or FM approved valves, or valves with supervisory (tamper) switches. Tell us what your specification requires.
Installation, testing and replacement
We install valves as part of new fire hydrant and sprinkler systems and pump rooms. On existing sites, our service visits check valves for leaks and seizing, and we replace faulty ones under our AMC. Our FireSense IoT monitoring can add continuous line-pressure and tank-level tracking on top of the valves.

Why choose Cease Fire
Since 1992
1,500+ fire protection projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).
Licensed
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ). See our certifications.RF-93/ RD-95 System knowledge
We design, install and maintain fire systems, so we specify each valve for its position, not just its size.
One supplier
Valves, fire pumps, hydrant accessories and installation from one team.
Request a valve quote
Send your BOQ or valve list with sizes, pressure rating and end connections. We will confirm the specification and quote.
Frequently asked questions
Which valves are used in fire fighting systems?
The main ones are butterfly and gate valves for isolation, non-return and check valves to stop backflow, air release valves, Y strainers and ball valves. Hydrant systems also use landing valves, and sprinkler systems use alarm and deluge valves.
Should I use a butterfly valve or a gate valve on a fire line?
Both isolate a line. A butterfly valve is compact and quick to operate with a quarter turn. A gate valve gives a full-bore opening with very low pressure loss.
What does a non-return valve do in a fire pump line?
It lets water flow out of the pump into the system but stops it flowing back, which protects idle pumps and holds pressure in the pipework. A swing check valve has a single hinged disc, while a dual plate check valve uses two spring-loaded plates in a short wafer body.
Why does a fire system need an air release valve?
Trapped air at high points reduces flow and can cause pressure surges. An air release valve lets the air out automatically.
What is a Y strainer used for?
It catches debris in the water before it reaches pumps, pressure reducing valves or control valves, where it could cause damage or blockages.
What pressure rating do fire fighting valves need?
The rating must be above the system's working pressure. Our flanged range is rated PN 1.6, 2.0 and 2.5 MPa.
Why does valve position matter for ACMS monitoring?
A closed isolation valve can cut off water to a hydrant or sprinkler zone. ACMS monitoring, required for covered buildings in Maharashtra since 12 June 2025, tracks line pressure and tank levels, and a drop can point to a valve problem. Supervisory (tamper) switches can add valve-position alerts if your specification calls for them.
Can you supply UL listed or FM approved valves?
Yes. UL listed and FM approved valves are available. Tell us what your consultant or insurer specifies, and we will share the manufacturer's certificate for the exact model with our quote.
How do I get a quote for fire fighting valves?
Send your BOQ or valve list to sales@ceasefireservices.com, call +91 9920676281, or use the enquiry form.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.