Fire Sprinklers and Accessories in Mumbai

Eight sprinkler heads in a row with an alarm valve, a flow switch and a flexible sprinkler hose behind them

Cease Fire & Electrical Services LLP supplies fire sprinklers and sprinkler accessories in Mumbai: pendent, upright, sidewall and ESFR sprinkler heads, alarm and deluge valves, water curtain nozzles, flow switches, annunciator panels and flexible sprinkler hoses. Because we design and install sprinkler systems ourselves, we match each head and valve to the hazard, ceiling and layout it protects.

Sprinkler heads we supply

Each head is chosen by its temperature rating, K-factor (flow), response type and finish. See drencher system for water curtains.

Sprinkler valves and accessories

Heads and valves chosen by the system designer

Sprinkler hardware only works as intended when it matches the design. Our engineers select heads, spacing and valves as part of sprinkler system design and installation, check pipe sizes with hydraulic calculations, and add seismic bracing where required.

Monitoring the sprinkler system

Flow switches tell the fire alarm panel which zone has water flow. For continuous monitoring of the water supply, our FireSense IoT panel tracks sprinkler and drencher line pressure, tank levels and pump status, and sends an SMS if data stops for 15 minutes. This supports the Automated Continuous Monitoring System (ACMS) required for covered buildings in Maharashtra since 12 June 2025.

Sprinklers on our projects

  • Engineer on a scissor lift tightening the clamp of a sway brace on a red sprinkler main under a warehouse roof

    Roquette India, Pantnagar

    Roof sprinklers, seismic bracing and fire alarm, to FM guidelines, in 4 godowns (January 2023 to February 2024).

  • Engineer crouching at a red yard fire hydrant, reading a pressure gauge, a fire brigade inlet on the wall beside it

    LBS IMU Mumbai Port Campus (CPWD), Sewri

    Fire fighting and sprinkler systems for a G + 11 hostel.

  • Engineer in a hard hat drawing the nozzle from a red hose reel in an open wall cabinet

    Palkhi Roha, Kandivali East (G + 14)

    Fire fighting, sprinkler, fire detection and signage systems.

  • Engineer reading the pressure gauge on a red riser valve above a four-way fire brigade inlet, at the entrance of a residential tower with a slatted, planted podium

    Palkhi MRDA, Kandivali (G + podium + 13)

    Fire fighting, sprinkler, fire detection and signage systems.

See our projects.

See all projects and case studies

Replacement and servicing

Painted, damaged or corroded heads must be replaced with heads of the same type, temperature rating and K-factor. Our service visits check sprinkler alarm valves, sprinkler heads and flow switches, and our AMC covers the whole system with quarterly checks and an annual service for most sites.

Why choose Cease Fire

  • Since 1992

    1,500+ fire protection projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).

  • Licensed

    Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95). We issue Form B certificates. See our certifications.

  • Design experience

    Sprinkler work to NFPA, NBC and FM guidelines, including warehouse roof sprinklers with seismic bracing.

  • One supplier

    Sprinklers, valves, fire pumps and installation from one team.

Request a sprinkler quote

Send your BOQ, drawings or a list of heads and valves, with the building type and location. We will confirm the specification and quote.

Frequently asked questions

What is the difference between pendent, upright and sidewall sprinklers?

A pendent sprinkler hangs down from the pipe, usually below a false ceiling. An upright sprinkler points up from exposed pipes. A sidewall sprinkler is fixed on a wall and sprays outwards into the room.

What is an ESFR sprinkler?

ESFR stands for early suppression, fast response. These heads discharge a large volume of water quickly to suppress fires in high-piled and rack storage, and are mainly used in warehouses.

What do the colours of sprinkler bulbs mean?

The colour shows the temperature at which the bulb breaks. For example, orange is 57 °C, red 68 °C, yellow 79 °C and green 93 °C. We choose the rating to suit the normal temperature of each area.

What is the difference between an alarm valve and a deluge valve?

An alarm valve is the main control valve of a wet system: when a closed head opens, water flows through it and it raises an alarm. A deluge valve serves open nozzles and releases water to all of them at once when a detection system triggers it.

What does a flow switch do in a sprinkler system?

It senses water flowing in a pipe when a sprinkler opens, and sends a signal to the fire alarm panel showing which floor or zone is affected.

What is a water curtain nozzle used for?

It is an open nozzle that forms a sheet of water, used in drencher systems to protect openings, escalator voids and building faces. It works with a deluge valve and a detection system.

Can sprinkler line pressure be monitored for ACMS?

Yes. Our FireSense IoT panel monitors hydrant, sprinkler and drencher line pressure along with pumps and tanks. ACMS has applied to covered buildings in Maharashtra since 12 June 2025.

Can I replace a sprinkler head with a different type?

Only if it matches the original in K-factor, temperature rating, response type and orientation, as the system was designed around them. Our engineers check this before replacing any head.

Can you supply UL listed or FM approved sprinklers?

Yes. UL listed and FM approved sprinklers and valves are available. Tell us what your consultant or insurer specifies, and we will share the manufacturer's certificate for each model with our quote.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.

Call +91 9920676281