Foam Fire Extinguisher in Mumbai

Cease Fire & Electrical Services LLP supplies ISI-marked mechanical foam fire extinguishers in Mumbai from our own CEASE FIRE range: 9 litre portable units and 50, 135 and 200 litre trolley units. A foam fire extinguisher uses AFFF (aqueous film forming foam) to put out Class A fires in solids and Class B fires in flammable liquids such as petrol, diesel, oils and paints. We supply, install, refill and service them under AMC.
CEASE FIRE foam extinguishers
| Model | Capacity | Operation | Fire rating | Jet range |
|---|---|---|---|---|
| MF09SG | 9 litre | CO2 gas cartridge, refillable at site | 3A-21B | 6 m |
| MF09SP | 9 litre | Stored pressure (nitrogen) with pressure gauge | Ask us | 6 m |
| MF09CT | 9 litre | Puncture-type cartridge | Ask us | 6 m |
| MF50CT | 50 litre trolley | Puncture-type CO2 cartridge | Ask us | 10 m |
| MF135CY | 135 litre trolley | CO2 cylinder with regulator valve | Ask us | 10 m |
| 200 litre | 200 litre trolley | CO2 cylinder with regulator valve | Ask us | Ask us |
The portable units use 6% AFFF, discharge at least 90% of their contents in 25 to 60 seconds and work from 0 °C to +55 °C. Bodies are powder-coated inside and out for corrosion resistance.
Where foam extinguishers are used
- Fuel, oil and paint stores
- Workshops, garages and car parks
- DG rooms and boiler areas with liquid fuel
- Factories and warehouses storing flammable liquids
- Loading bays and tanker areas (trolley units)
- Foam is water-based, so it must not be used on live electrical equipment. Use CO2 or clean agent for electrical risks.
Standards
Our portable foam extinguishers are designed to IS 15683 and carry the BIS ISI mark.
Supply, installation and servicing
We recommend portable and trolley units for each liquid-fire risk, place them with signage, and keep them ready with inspection, foam replacement, refilling and hydro-testing, as a one-time service or under AMC.

Why choose Cease Fire
Our own ISI-marked range
9 litre portable to 200 litre trolley foam units.
Foam systems too
We also design and install foam flooding systems for larger liquid-fire risks.
Since 1992
Supply, refilling and AMC from one licensed team.
Request a quote
Tell us the sizes and quantities you need, or the areas you want to protect. We will send a quote or arrange a site visit.
Frequently asked questions
What is a foam fire extinguisher used for?
It is used on Class A fires in wood, paper and cloth, and Class B fires in flammable liquids such as petrol, diesel, oils and paints. The foam forms a blanket that cuts off air and stops re-ignition.
What is AFFF in a fire extinguisher?
AFFF stands for aqueous film forming foam. It spreads a thin film over the burning liquid that seals in flammable vapours and cools the fuel.
Can a foam extinguisher be used on electrical fires?
No. Foam contains water and can conduct electricity, so it must not be used on live electrical equipment. Use a CO2 or clean agent extinguisher instead.
What is the difference between a foam and a water fire extinguisher?
A water extinguisher is only for Class A fires in solids. A foam extinguisher also works on flammable liquid fires, because the foam floats on the liquid and seals it.
How often should a foam extinguisher be refilled?
It must be refilled after any use, and the foam solution is replaced when due at servicing. We inspect, refill and hydro-test foam extinguishers under AMC.
Do you supply foam trolley extinguishers?
Yes. Our CEASE FIRE range includes 50, 135 and 200 litre foam trolley units for larger liquid-fire risks.
Can a foam extinguisher be used on a petrol fire?
Yes. The foam floats on petrol, diesel and oils and seals the liquid from the air. It must not be used on live electrical equipment.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281