Fire Stop Sealant System in Mumbai
Cease Fire & Electrical Services LLP supplies and installs fire stop sealant systems in Mumbai to seal the gaps around pipes, cables, ducts and joints where they pass through fire-rated walls and floors. We use fire-rated foam, sealants, pipe wraps and fire-resistant putty cord, chosen for each opening, so fire and smoke cannot pass from one room or floor to the next. We sealed the service shafts with fire sealant and fire-rated foam for Prime Smile, a G + 22 residential tower in Borivali West.
Why gaps around services matter
A fire-rated wall or floor is only as good as its weakest opening. Every pipe, cable tray or duct that passes through leaves a gap, and plastic pipes and cable insulation burn away in a fire, leaving a hole. Without fire stopping, fire and smoke travel through these gaps and along shafts to other floors, often faster than through the rooms themselves.
Products we use
Fire-rated foam
What it doesExpands to fill irregular gaps and cavities
Typical useGaps around pipe and cable bunches, small shaft openings
Fire stop sealant
What it doesSeals small gaps and joints; intumescent types expand in heat
Typical useAround single pipes and cables, wall and floor joints
Pipe wrap
What it doesExpands in a fire and closes off the hole left by a burning plastic pipe
Typical usePlastic pipes and pipes with combustible insulation
Fire-resistant putty cord
What it doesA mouldable seal for small gaps
Typical useCable and pipe penetrations, electrical boxes
Fire-retardant coatings
What it doesSlow the spread of flame on cables and services
Typical useCable trays and service routes near a seal
Larger shaft openings are sealed with fire-stop mortar.
Installed as a tested system
A fire stop sealant only works as part of a tested system: the right product, in the right depth, with the right backing such as mineral wool, around the right type of pipe or cable. We match each opening to the product and method for it, and record every seal we install.
Where fire sealants are used
- Electrical, plumbing and service shafts at each floor
- Cable trays and cable bunches through walls and floors
- Plastic drainage and water pipes through slabs
- Gaps around ducts and at wall and floor joints
- Openings left by other trades during fit-outs
Our process
Free site survey
We inspect shafts and penetrations and list every opening to be sealed.
Proposal
The right product and method for each opening, with quantities.
Supply and installation
Backing, sealant, foam, pipe wraps and putty, installed by our own team.
Inspection and handover
Each sealed opening is checked and recorded, with photos.
Form A
As a licensed agency, we issue Form A for the fire protection work we complete.
Ongoing checks
New openings made later by other trades are the most common failure, so we can re-inspect under AMC.
Fire sealant project
Prime Smile, Borivali West (G + 22 residential tower), 2024–25: supply and installation of fire sealant for the service shafts and fire-rated foam, with Form A for the fire doors.
See all projects and case studies.
Why choose Cease Fire
Since 1992
1,500+ projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).
Complete range
Foam, sealants, mortar, pipe wraps, putty cord and coatings from one team.
Licensed
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ).RF-93/ RD-95 Audit experience
Our fire safety audits check compartmentation, so we know what inspectors look for.
Book a free site survey
Send photos of your shafts and openings, the building type and number of floors. We will inspect the openings and send a clear proposal.
Frequently asked questions
What is a fire stop sealant?
It is a fire-resistant sealant used to close the gaps around pipes, cables and joints in fire-rated walls and floors. It stops fire and smoke passing through the gap.
What is the difference between fire-rated foam and fire sealant?
Fire-rated foam expands to fill larger, irregular gaps and cavities. Sealant is used for smaller gaps and joints and is applied with a gun.
What does intumescent mean?
An intumescent product swells when heated. This fills the space left when plastic pipes or cable insulation burn away in a fire.
Why do plastic pipes need a pipe wrap?
Plastic pipes soften and burn away in a fire, leaving a hole. A pipe wrap expands and closes that hole.
Can fire stopping be added to an existing building?
Yes. We survey the existing shafts and openings, then seal them floor by floor with minimal disruption to residents or occupants.
How long does a fire stop seal last?
A seal lasts as long as nobody disturbs it. New cables or pipes pushed through later break the seal, so openings should be checked after fit-outs.
Do you issue Form A for fire stopping work?
As a Maharashtra Fire Services Licensed Agency, we issue Form A for the fire protection work we complete.
Have you installed fire sealant in a high-rise tower?
Yes. We supplied and installed fire sealant for the service shafts, with fire-rated foam, at Prime Smile, a G + 22 residential tower in Borivali West, 2024 to 2025. See the project page.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281