
Fire Safety for Residential Towers and Societies in Mumbai
Cease Fire & Electrical Services LLP installs and maintains fire safety systems for residential towers, redevelopment projects and housing societies in Mumbai: wet risers and hydrants, sprinklers, fire alarms, fire pumps, passive fire protection, signage and IoT monitoring. We work with developers during construction and with societies after handover. As a licensed agency since 1992, we issue Form A on completion and Form B every January and July. Residential projects include Palkhi Roha, Palkhi MRDA, Prime Smile, Neo Smile Developers and Godrej The Gale.
For developers and for societies
What you need
Developers (new towers and redevelopment)Fire systems designed, installed and certified before occupation
Housing societies (occupied buildings)Systems kept working, and Form B every January and July
What we do
Developers (new towers and redevelopment)Design, supply, installation, testing and commissioning, then Form A
Housing societies (occupied buildings)Residential AMC, Form B, repairs and upgrades
Monitoring
Developers (new towers and redevelopment)FireSense IoT panel installed with the systems
Housing societies (occupied buildings)FireSense IoT added to existing pump room and tanks
Where to start
Developers (new towers and redevelopment)Share your drawings and the fire authority's requirements
Housing societies (occupied buildings)Book a free site survey of your building
Fire systems in a residential tower
- Staircases and lobbies
- Wet riser with landing valves and hose boxes, hose reels, manual call points, detectors and signage
- Flats and common areas
- Sprinklers where the building's height requires them, and fire alarm devices
- Underground tank and pump room
- Main electric, diesel engine and jockey fire pumps
- Terrace tank
- Terrace booster pump for the top floors
- Refuge floors
- Refuge area signage, with the floor kept open and clear
- Shafts and fire exits
- Fire sealants for service shafts and fire doors
- Basement and podium parking
- Sprinklers and hydrants
- Building entrance
- Fire brigade inlet so fire tenders can pump water into the system
- Pump room, tanks and alarm panel
- FireSense IoT panel for continuous status and alerts
See fire hydrant system, sprinkler system and fire alarm system.
Residential projects we have delivered

Palkhi Roha, Kandivali East (G + 14)
Fire fighting, sprinkler, fire detection and signage systems, for YogSiddhi Palkhi Developers. Completed April 2024.

Palkhi MRDA, Kandivali, for KCD Realty (G + podium + 13)
Fire fighting, sprinkler, fire detection and signage systems.

Prime Smile, Borivali West (G + 22)
1-hour fire-rated board with acrylic sealant for fire and electrical shafts, fire-rated foam, and Form A documentation for fire doors (2024 to 2025).
Neo Smile Developers, Borivali West
Our FireSense IoT panel for continuous monitoring of the building's fire systems, installed in July 2025.
Godrej The Gale
Residential project.
Our residential clients include Lodha and Godrej. See our projects.
See all projects and case studiesMonitoring for towers and societies
Towers rely on pumps, tanks and risers that can fail without anyone noticing. The Maharashtra fire rules amended on 12 June 2025 introduced an Automated Continuous Monitoring System (ACMS) for covered buildings. A licensed agency certifies the installed system on Form A-1, and the owner files Form B-1 in January and July. Our FireSense IoT panel tracks fire pump status, water tank levels, hydrant and sprinkler line pressure and fire alarm panel status, and alerts the society's contacts. Read the ACMS Form A-1 and B-1 guide, or the Neo Smile case study.
Keeping an older society compliant
Many older societies find problems only when Form B is due. Common issues include pumps that do not start on test, missing hoses and nozzles, closed or seized valves, and extinguishers overdue for refilling. Our residential AMC checks most systems every quarter, services them once a year and keeps Form B on time. If you need a full review first, we carry out fire safety audits and can train residents and staff.
Why choose Cease Fire
Since 1992
1,500+ fire protection projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).
Licensed
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ) and Fire and Life Safety Auditor. See our certifications.RF-93/ RD-95 Construction to handover and beyond
One team from design and Form A to AMC, Form B and monitoring.
Free site survey across Mumbai, Thane and Navi Mumbai.
Book a free site survey
Tell us your building's name, location and number of floors, and whether it is under construction or occupied. We will inspect it and recommend the next steps.
Frequently asked questions
Is Form B mandatory for housing societies in Mumbai?
Yes. Under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, owners and occupiers must submit a Form B certificate from a licensed agency every January and July. It confirms the fire systems are maintained and working.
What fire safety systems does a high-rise residential building need?
It depends on the building's height, as set out in the NBC and the Maharashtra Fire Act. Towers usually need a wet riser or hydrant system, hose reels, fire pumps, a fire brigade inlet, fire detection and alarm, signage and fire doors. Taller buildings also need sprinklers and refuge areas.
What is ACMS and does my society need it?
ACMS is the Automated Continuous Monitoring System introduced by the Maharashtra fire rules amended on 12 June 2025, for covered buildings. A licensed agency certifies it on Form A-1, and the owner files Form B-1 in January and July. Ask your fire officer whether your building is covered; we can supply and certify the monitoring.
What is a refuge area?
It is an open, fire-safe area on certain floors of a high-rise building where residents can wait safely for rescue. It must be kept clear and must not be enclosed or used for other purposes.
Who is responsible for fire safety in a housing society?
The society, through its managing committee, is responsible for the building's fire systems and Form B. Residents should keep their own flats safe and not block staircases, lobbies or refuge areas.
Why does our tower need a terrace booster pump?
The terrace tank is close to the top floors, so gravity alone gives little pressure there. A booster pump raises the pressure so hoses and sprinklers on the upper floors work properly.
Can you upgrade the fire system in an old building?
Yes. We survey the building, report what is missing or not working, and upgrade the systems in stages if needed.
Do you work with developers on redevelopment projects?
Yes. We design, install and commission fire systems for new and redeveloped towers, and issue Form A on completion.
How do I book a site survey for our society?
Call +91 9920676281, email sales@ceasefireservices.com, or use the enquiry form. The site survey is free.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281





