Engineer checking a hose reel cabinet in the lift lobby of a residential tower

Fire Safety for Residential Towers and Societies in Mumbai

Cease Fire & Electrical Services LLP installs and maintains fire safety systems for residential towers, redevelopment projects and housing societies in Mumbai: wet risers and hydrants, sprinklers, fire alarms, fire pumps, passive fire protection, signage and IoT monitoring. We work with developers during construction and with societies after handover. As a licensed agency since 1992, we issue Form A on completion and Form B every January and July. Residential projects include Palkhi Roha, Palkhi MRDA, Prime Smile, Neo Smile Developers and Godrej The Gale.

For developers and for societies

  1. What you need

    Fire systems designed, installed and certified before occupation

    Systems kept working, and Form B every January and July

  2. What we do

    Design, supply, installation, testing and commissioning, then Form A

    Residential AMC, Form B, repairs and upgrades

  3. Monitoring

    FireSense IoT panel installed with the systems

    FireSense IoT added to existing pump room and tanks

  4. Where to start

    Share your drawings and the fire authority's requirements

    Book a free site survey of your building

Fire systems in a residential tower

Staircases and lobbies
Wet riser with landing valves and hose boxes, hose reels, manual call points, detectors and signage
Flats and common areas
Sprinklers where the building's height requires them, and fire alarm devices
Underground tank and pump room
Main electric, diesel engine and jockey fire pumps
Terrace tank
Terrace booster pump for the top floors
Refuge floors
Refuge area signage, with the floor kept open and clear
Shafts and fire exits
Fire sealants for service shafts and fire doors
Basement and podium parking
Sprinklers and hydrants
Building entrance
Fire brigade inlet so fire tenders can pump water into the system
Pump room, tanks and alarm panel
FireSense IoT panel for continuous status and alerts

See fire hydrant system, sprinkler system and fire alarm system.

Residential projects we have delivered

  • Engineer in a hard hat drawing the nozzle from a red hose reel in an open wall cabinet

    Palkhi Roha, Kandivali East (G + 14)

    Fire fighting, sprinkler, fire detection and signage systems, for YogSiddhi Palkhi Developers. Completed April 2024.

  • Engineer reading the pressure gauge on a red riser valve above a four-way fire brigade inlet, at the entrance of a residential tower with a slatted, planted podium

    Palkhi MRDA, Kandivali, for KCD Realty (G + podium + 13)

    Fire fighting, sprinkler, fire detection and signage systems.

  • Engineer kneeling at an open electrical shaft in an apartment corridor, sealing round the cable trays at floor level with a sealant gun

    Prime Smile, Borivali West (G + 22)

    1-hour fire-rated board with acrylic sealant for fire and electrical shafts, fire-rated foam, and Form A documentation for fire doors (2024 to 2025).

  • Neo Smile Developers, Borivali West

    Our FireSense IoT panel for continuous monitoring of the building's fire systems, installed in July 2025.

  • Godrej The Gale

    Residential project.

Our residential clients include Lodha and Godrej. See our projects.

See all projects and case studies

Monitoring for towers and societies

Towers rely on pumps, tanks and risers that can fail without anyone noticing. The Maharashtra fire rules amended on 12 June 2025 introduced an Automated Continuous Monitoring System (ACMS) for covered buildings. A licensed agency certifies the installed system on Form A-1, and the owner files Form B-1 in January and July. Our FireSense IoT panel tracks fire pump status, water tank levels, hydrant and sprinkler line pressure and fire alarm panel status, and alerts the society's contacts. Read the ACMS Form A-1 and B-1 guide, or the Neo Smile case study.

Keeping an older society compliant

Many older societies find problems only when Form B is due. Common issues include pumps that do not start on test, missing hoses and nozzles, closed or seized valves, and extinguishers overdue for refilling. Our residential AMC checks most systems every quarter, services them once a year and keeps Form B on time. If you need a full review first, we carry out fire safety audits and can train residents and staff.

Why choose Cease Fire

  • Since 1992

    1,500+ fire protection projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).

  • Licensed

    Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95) and Fire and Life Safety Auditor. See our certifications.

  • Construction to handover and beyond

    One team from design and Form A to AMC, Form B and monitoring.

  • Free site survey across Mumbai, Thane and Navi Mumbai.

Book a free site survey

Tell us your building's name, location and number of floors, and whether it is under construction or occupied. We will inspect it and recommend the next steps.

Frequently asked questions

Is Form B mandatory for housing societies in Mumbai?

Yes. Under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, owners and occupiers must submit a Form B certificate from a licensed agency every January and July. It confirms the fire systems are maintained and working.

What fire safety systems does a high-rise residential building need?

It depends on the building's height, as set out in the NBC and the Maharashtra Fire Act. Towers usually need a wet riser or hydrant system, hose reels, fire pumps, a fire brigade inlet, fire detection and alarm, signage and fire doors. Taller buildings also need sprinklers and refuge areas.

What is ACMS and does my society need it?

ACMS is the Automated Continuous Monitoring System introduced by the Maharashtra fire rules amended on 12 June 2025, for covered buildings. A licensed agency certifies it on Form A-1, and the owner files Form B-1 in January and July. Ask your fire officer whether your building is covered; we can supply and certify the monitoring.

What is a refuge area?

It is an open, fire-safe area on certain floors of a high-rise building where residents can wait safely for rescue. It must be kept clear and must not be enclosed or used for other purposes.

Who is responsible for fire safety in a housing society?

The society, through its managing committee, is responsible for the building's fire systems and Form B. Residents should keep their own flats safe and not block staircases, lobbies or refuge areas.

Why does our tower need a terrace booster pump?

The terrace tank is close to the top floors, so gravity alone gives little pressure there. A booster pump raises the pressure so hoses and sprinklers on the upper floors work properly.

Can you upgrade the fire system in an old building?

Yes. We survey the building, report what is missing or not working, and upgrade the systems in stages if needed.

Do you work with developers on redevelopment projects?

Yes. We design, install and commission fire systems for new and redeveloped towers, and issue Form A on completion.

How do I book a site survey for our society?

Call +91 9920676281, email sales@ceasefireservices.com, or use the enquiry form. The site survey is free.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.

Call +91 9920676281