Y Strainer for Fire Fighting Systems in Mumbai

Cease Fire & Electrical Services LLP supplies the Y strainer for fire fighting and water lines in Mumbai, with a flanged cast iron body and a stainless steel screen, in 25 mm to 300 mm sizes. A Y strainer catches debris in the water before it reaches pumps, pressure reducing valves, control valves or spray nozzles, where it could cause damage or blockages. We supply and fit Y strainers as part of pump room, water spray and hydrant work, and clean them during AMC visits.
Specifications
- Sizes
- 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250 and 300 mm (1 to 12 inch)
- Body and cover
- Cast iron to IS 210 FG 200
- Screen
- Stainless steel SS 304
- Gasket
- Nitrile rubber
- Bolts and nuts
- Carbon steel to IS 1363
- Drain plug
- Cast iron
- Flanges
- Class 150 or Table E
Screen mesh size and test pressure: ask us for the datasheet.
Where Y strainers are used in fire systems
- Ahead of pressure reducing valves: on risers and branches where a PRV controls outlet pressure.
- Water spray and deluge systems: to stop debris blocking spray nozzles or control valve trim.
- Pump lines: where the design calls for one, for example when a pump draws from an open tank or a raw water source.
- Small control devices: ahead of solenoid valves and other devices with fine passages.
- A blocked strainer restricts flow. On a fire pump suction this can starve the pump, so a strainer there should only be fitted where the design needs it, and must be cleaned on a schedule.
Installation and cleaning
- Fit the strainer with the arrow on the body pointing in the direction of flow.
- In a horizontal line, point the screen leg downward so debris collects away from the flow. In a vertical line, fit it with the flow going downward.
- Leave room to remove the cover and screen, and fit isolation valves either side where the line cannot be shut down easily.
- Clean the screen after commissioning, when the first flush brings out construction debris, and then at every maintenance visit.

Why choose Cease Fire
Since 1992
A Maharashtra Fire Services Licensed Agency (MFS/
LA/ ) with 1,500+ projects.RF-93/ RD-95 System view
We design, install and maintain pump rooms and water spray systems, so we place strainers where they protect equipment without starving it.
One supplier
Strainers, valves, fire pumps and installation from one team.
Request a valve quote
Send your list with sizes, quantity and flange standard. We will confirm the specification and quote.
Frequently asked questions
What is a Y strainer used for?
It catches debris in the water before it reaches pumps, pressure reducing valves or control valves. This prevents damage, blockages and valves that fail to seal.
Why is it called a Y strainer?
The body is shaped like the letter Y. The screen sits in the angled leg, where debris collects without blocking the main flow.
Where should a Y strainer be installed in a fire system?
Ahead of pressure reducing valves, deluge and water spray control valves, and small devices with fine passages. On a pump suction, fit one only if the design calls for it.
How often should a Y strainer be cleaned?
After commissioning, and then at every maintenance visit. Clean it sooner if pressure downstream drops or the water supply carries a lot of dirt.
What is the difference between a Y strainer and a basket strainer?
A Y strainer is compact and suits most pipe runs. A basket strainer holds more debris, so it suits lines with heavy dirt loads, but it is larger.
What sizes do you supply?
We supply flanged cast iron Y strainers from 25 mm to 300 mm, with stainless steel screens.
Do you clean strainers during AMC visits?
Yes. We remove and clean the screen at each maintenance visit and replace strainers that are damaged or blocked.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281