
Public Address System Installation in Mumbai
Cease Fire & Electrical Services LLP provides public address system installation in Mumbai for residential towers, offices, hospitals, schools, factories and commercial buildings. A building PA system uses amplifiers, speakers and call stations to give clear voice instructions floor by floor, and it can be linked to the fire alarm so evacuation messages take priority. We design, supply, install and test the complete system and maintain it with your fire alarm under AMC.
Why a PA system matters in a fire
A hooter tells people something is wrong, but not what to do. A voice message can tell them which floor is affected, which stairs to use and whether to leave now or wait. Clear instructions help avoid crowding on the stairs, especially in tall buildings where floors are evacuated in stages. Day to day, the same system handles paging, announcements and background music.
How a building PA system works
- Call station or microphone: staff speak into a desk call station or microphone and choose the zones to address.
- Amplifier: raises the voice to a 100 V line so the signal can run hundreds of metres on thin cable to many speakers.
- Speakers: each speaker is set to a power tap, such as 1.5 W, 3 W or 6 W, to suit the area.
- Zones: each floor or area is a separate zone, so messages can go to one zone, several zones or all zones.
- Fire alarm link: when linked to the fire alarm panel, an alarm can trigger evacuation announcements that override music and paging.
Components of a PA system

PA amplifier
Drives the 100 V speaker line for each zone

Zone call station
Desk microphone with zone buttons for floor-by-floor announcements

PA microphone
Paging microphone for the reception or control room

Ceiling speakers
For offices, corridors and lobbies with false ceilings

Wall and column speakers
For rooms and halls without false ceilings

Horn speakers
For car parks, plant rooms, factories and outdoor areas

PA hooters
Combined hooter and speaker units for alarms and announcements

Speaker cabling
Runs each zone from the amplifier to its speakers
We supply the amplifiers, speakers, microphones and call stations ourselves.
Where PA systems are used

Residential towers
A speaker on each floor lobby and in common areas, with a call station at the security desk

Offices and commercial buildings
Ceiling speakers on every floor, zone-wise paging and evacuation messages

Hospitals and schools
Zoned announcements for wards, classrooms and corridors

Factories and warehouses
Horn speakers loud enough to be heard over machinery
Design
We design the PA system with the fire alarm, so zones match the fire alarm zones and floors. Speaker type and tap are chosen for each area's size, ceiling height and background noise. The amplifier is sized to the total of the speaker taps in each zone, with a reserve of about 10% to 20%. IS 2189 recognises emergency voice alarm communication as part of fire detection and alarm systems, and EN 54-16 and EN 54-24 are the European standards for voice alarm amplifiers and speakers.
Our process
Free site survey
We review the building, floors and areas to cover, and any existing PA or fire alarm system.
Design
Zones, speaker layout and taps, amplifier sizing, call station positions and the link to the fire alarm.
Supply and installation
Amplifiers, speakers, microphones, call stations and cabling, installed by our own team.
Testing and commissioning
Every zone and speaker tested for clarity and level, fire alarm link checked, and staff trained.
Form A
As a licensed agency, we issue Form A for the fire safety work, which you submit to the fire brigade.
AMC and Form B
Usually quarterly checks with an annual service, and Form B every January and July.
Fire alarm projects

Adani Electricity Mumbai
Addressable fire alarm systems at 65 receiving substations across Mumbai, May 2024 to January 2026.

Palkhi Roha, Kandivali East (G + 14)
Fire detection with fire fighting, sprinklers and signage, completed in April 2024.

Palkhi MRDA, Kandivali (G + podium + 13), for KCD Realty
The same complete package.
Maintenance and Form B
Speakers get painted over, disconnected during fit-outs or damaged, and a silent zone is only found when it is needed. Under AMC we test every zone, check the amplifiers and call stations, and test the link from the fire alarm panel. A licensed agency must inspect the fire systems and issue Form B every January and July, and we can include this in your AMC.
Why choose Cease Fire
Since 1992
1,500+ projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).
PA and fire alarm together
One team designs both, so zones and messages match.
Licensed
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ) and Maharashtra Electrical Contractor Licence No. 17545.RF-93/ RD-95 One team
Equipment, installation, testing and AMC from one company.
Book a free site survey
Send your floor plan and tell us which areas need announcements. We will survey the site and send a clear proposal.
Frequently asked questions
What is a public address system in a building?
It is a system of amplifiers, speakers and microphones or call stations that lets staff make announcements across the building, floor by floor or to all areas at once.
Why does a building need a PA system for fire safety?
Voice messages tell people which floor is affected and what to do, which a hooter cannot. This helps manage evacuation, especially in tall buildings.
Can the PA system be linked to the fire alarm?
Yes. The fire alarm panel can trigger evacuation announcements that override music and paging in the affected zones.
What is a 100 V line PA system?
The amplifier sends the signal at 100 V so it can travel long distances on thin cable. Each speaker has a small transformer and a power tap, and all speakers connect in parallel.
What is a zone call station?
It is a desk microphone with buttons for each zone. Staff choose one floor, several floors or all zones before speaking.
Which speakers are used in a PA system?
Ceiling speakers suit offices and lobbies with false ceilings, wall and column speakers suit halls, and horn speakers suit car parks, factories and outdoor areas.
How often should a PA system be tested?
We test every zone during AMC visits, usually quarterly with an annual service, together with the fire alarm. A licensed agency must also inspect the fire systems for Form B every January and July.
Can a PA system be added to an existing building?
Yes. We survey the ceilings and cable routes, add speakers zone by zone and link the system to the fire alarm panel if the building has one.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281

