Fire Alarm System Installation in Mumbai
Cease Fire & Electrical Services LLP provides fire alarm system installation in Mumbai: conventional, addressable and wireless fire detection and alarm systems designed to IS 2189 and NFPA 72. We supply, install, test and maintain the panel, detectors, call points and sounders for offices, housing societies, factories, hospitals and utility sites. Our recent work includes addressable fire alarm systems at 65 Adani Electricity receiving substations across Mumbai.
How a fire alarm system works
Detectors watch for smoke or heat in every area, and manual call points let anyone raise the alarm by hand. When a device operates, the fire alarm panel sounds the hooters and strobes, shows where the fire is, and can signal other systems, such as the public address system, sprinkler flow switches or a gas suppression panel. The earlier a fire is detected, the more time people have to leave safely.
Types of fire alarm systems we install
Conventional
How it worksDevices are wired in zones; the panel shows which zone is in alarm
Best suited toSmaller buildings, shops and small offices
Semi-addressable
How it worksAddressed devices plus conventional zones on one system; the panel shows the device for addressed parts and the zone for the rest
Best suited toMid-sized buildings that need more detail than zones alone
Addressable
How it worksEvery device has its own address, so the panel shows the exact detector or call point
Best suited toLarge buildings, campuses, hospitals and industrial sites
Wireless
How it worksDetectors and sounders communicate by radio with the panel
Best suited toHeritage buildings, occupied offices and sites where new cabling is difficult
We also install public address (PA) systems for voice announcements and evacuation messages.
Components of a fire alarm system

Fire alarm control panel
Receives signals from all devices, sounds the alarm and shows the location

Smoke detectors
Detect smoke early in rooms, corridors and lobbies

Heat detectors (fixed temperature and rate of rise)
Detect heat in kitchens, car parks and dusty areas where smoke detectors would false-alarm

Manual call points (break glass and push type)
Let people raise the alarm by hand

Hooters, strobes and sounders
Warn everyone in the building to evacuate

Monitor, control and isolator modules
Connect other equipment to an addressable loop and protect the loop from short circuits

Response indicators
Show outside a closed room that a detector inside has operated

PA amplifiers, speakers and call stations
Give clear voice instructions during an evacuation
We supply all of these devices, from panels to detectors and PA equipment.
Design standards
We design fire detection and alarm systems to IS 2189 and NFPA 72, and to FM guidelines where the insurer requires them, as on our Roquette India project. Detector type and spacing are chosen for each room's height, use and airflow, and the cabling is laid out so the system can be extended later.
Our process
Free site survey
We review the building, room uses and any existing system.
Design
System type, device layout, zoning or loop design and cable routes.
Supply and installation
Panel, detectors, call points, sounders and cabling, installed by our own team.
Testing and commissioning
Every device tested, panel programmed, links to other systems checked, and staff trained.
Form A
As a licensed agency, we issue Form A for the work, which you submit to the fire brigade.
AMC and Form B
Usually quarterly checks with an annual service, and Form B every January and July.
Fire alarm monitoring under ACMS
The Maharashtra ACMS rules of 12 June 2025 require the fire alarm panel to be monitored continuously in covered buildings. FireSense IoT reports the panel and repeater status, battery condition, detection faults and manual call point operation, and also the PA system, so a dead battery or a faulty loop is flagged at once. The owner and the licensed agency receive the alert. See our ACMS guide or FireSense IoT monitoring.
Fire alarm projects

Adani Electricity Mumbai
Supply, installation, testing and commissioning of addressable fire alarm systems at 65 receiving substations across Mumbai, May 2024 to January 2026, completed within the contract period.

Roquette India, Pantnagar
Fire alarm systems to FM guidelines, with roof sprinklers and seismic bracing, for four godowns.

Palkhi Roha, Kandivali East (G + 14)
Fire detection with fire fighting, sprinklers and signage, completed in April 2024.

Palkhi MRDA, Kandivali (G + podium + 13), for KCD Realty
The same complete package.
Maintenance and Form B
Detectors collect dust, batteries age and devices get covered or damaged during fit-outs. Under AMC we test the panel, detectors, call points and sounders, check the standby batteries, and record and rectify faults. A licensed agency must inspect the fire systems and issue Form B every January and July, and we can include this in your AMC.
Why choose Cease Fire
Since 1992
1,500+ projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).
Fire and electrical licences
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ) and Maharashtra Electrical Contractor Licence No. 17545.RF-93/ RD-95 Large-scale delivery
Addressable fire alarms at 65 Adani Electricity substations.
Every system type
Conventional, semi-addressable, addressable, wireless and PA.
One team
Design, devices, installation, testing and AMC from one company.
Book a free site survey
Tell us your building type, floor area and location, and send drawings if you have them. We will recommend the right system and send a clear proposal.
Frequently asked questions
What is the difference between a conventional and an addressable fire alarm system?
A conventional system groups devices into zones, so the panel shows only which zone is in alarm. An addressable system gives every device its own address, so the panel shows the exact detector or call point that operated.
Which fire alarm system is right for my building?
Conventional systems suit smaller buildings, while addressable systems suit large buildings and sites where finding the exact device quickly matters. We recommend the right type after a free site survey.
Do you install wireless fire alarm systems?
Yes. Wireless systems suit buildings where running new cables is difficult or disruptive.
What standards do you follow for fire alarm systems?
We design fire detection and alarm systems to IS 2189 and NFPA 72, and to FM guidelines where the insurer requires them.
Can the fire alarm be connected to sprinklers and a PA system?
Yes. Sprinkler flow switches connect to the panel through control modules, and the panel can trigger the public address system for evacuation announcements.
How often should a fire alarm system be tested?
Most sites have quarterly checks and an annual service under AMC, plus the Form B inspection by a licensed agency every January and July.
Why does my fire alarm keep giving false alarms?
Common causes are dusty or dirty detectors, the wrong detector type for the area, such as smoke detectors in kitchens, and wiring faults. A service visit finds and fixes the cause.
Can the fire alarm panel be monitored remotely?
Yes. FireSense IoT monitoring reports panel, repeater, battery, detector and call point status, which supports the ACMS required for covered buildings in Maharashtra.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281