Fire Safety FAQs
Short answers to the fire safety questions building owners, housing societies and facility managers ask us most. Cease Fire & Electrical Services LLP has been a Maharashtra Fire Services licensed agency since 1992, with 1,500+ fire protection projects; for advice on your own building, ask our team or book a free site survey.
Rules and compliance
What is Form B?
Form B is a certificate from a licensed agency confirming that a building's fire systems are maintained and working. Under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, owners and occupiers must submit it every January and July.
What is the difference between Form A and Form B?
Form A is issued by the licensed agency when fire systems are installed or changed. Form B is the six-monthly certificate that they are still maintained and working.
Who issues the fire NOC?
The fire brigade issues the fire NOC after its own inspection. A licensed agency installs and certifies the systems, but cannot issue the NOC itself.
Who is responsible for fire safety in a building?
The Maharashtra Fire Act places the duty on both owners and occupiers. In a housing society, the managing committee is usually responsible for common-area systems and Form B.
Is a fire safety audit mandatory?
The Maharashtra Fire Act requires fire and life safety audits for certain buildings, and hospitals and schools have been directed to carry out safety audits. Insurers and tenants often ask for one too. See Fire Safety Audit.
ACMS and IoT monitoring
What is ACMS?
ACMS is the Automated Continuous Monitoring System introduced by Maharashtra's fire rules amendment of 12 June 2025 for covered buildings. It uses IoT devices to report the status of fire protection systems such as pumps, tanks, line pressure and the fire alarm panel. See our ACMS guide.
What are Form A-1 and Form B-1?
Form A-1 is the licensed agency's certificate that the ACMS is provided. Form B-1 is filed by the owner twice a year, in January and July.
Is my building covered by ACMS?
It depends on the building and the rules. Ask your fire officer or a licensed agency; we can check it during a free site survey.
What does the FireSense IoT panel monitor?
It monitors the fire alarm panel status, fire MCC panel energy, current, voltage and frequency, pump status, hydrant, sprinkler and drencher line pressure and tank levels. It sends data every minute and an SMS if no data arrives for 15 minutes. See Fire IoT Monitoring System.
AMC and maintenance
What does a fire safety AMC include?
An annual maintenance contract covers regular checks, servicing and repairs of your fire systems, such as pumps, hydrants, sprinklers, alarms and extinguishers. Most systems get quarterly checks and an annual service. See AMC Services.
What is the difference between a comprehensive and a non-comprehensive AMC?
A comprehensive AMC includes the cost of most spare parts and repairs. A non-comprehensive AMC covers checks and servicing, and parts are charged separately.
Can you issue Form B under an AMC?
Yes. As a licensed agency, we issue Form B every January and July for the systems we maintain.
How often should fire extinguishers be refilled?
Refill an extinguisher after every use, and whenever a check shows low pressure or weight. Otherwise follow the manufacturer's instructions and the service schedule in IS 2190. We check and tag extinguishers during AMC visits.
Why won't our fire pump start on test?
Common causes are the pump or panel left in manual mode, a closed valve, a flat diesel battery or low fuel, or a faulty pressure switch. Call a licensed agency to check it; a pump that doesn't start is a serious risk.
Fire systems
What is the difference between a hydrant and a sprinkler system?
A hydrant system gives people and the fire brigade water through hoses to fight a fire. A sprinkler system works on its own: heads above the fire open automatically and spray water.
What is the difference between a hose reel and a hydrant hose?
A hose reel has a 19 mm or 25 mm hose on a drum for occupants to tackle a small fire early. A hydrant hose is 63 mm, delivers far more water and is used by trained staff or the fire brigade.
Addressable or conventional fire alarm: which do I need?
A conventional system shows the zone where a fire is detected; an addressable system shows the exact device. Addressable systems suit larger buildings. See Fire Alarm System.
What protects a server room without water?
A clean agent gas system puts out the fire without water or residue. We install Honeywell ECS FK-5-1-12 (Novec 1230 type) and FM-200 systems designed to NFPA 2001. See Fire Suppression System.
What is a kitchen fire suppression system?
It is a fixed system over the cooking range that sprays a wet chemical on burning oil and shuts off the fuel. We supply UL 300 systems from Lehavot and INTIME. See kitchen wet chemical suppression.
What is passive fire protection?
It is building elements, such as fire doors, fire sealants and fire-rated boards, that stop fire and smoke spreading between areas. See Passive Fire Protection.
Can you supply UL listed or FM approved equipment?
Yes, where your consultant or insurer specifies it. We share the manufacturer's certificate for the exact model with our quote.
Extinguishers and equipment
Which fire extinguisher do I need?
ABC extinguishers cover most general and electrical risks. CO2 suits electrical equipment, K-class wet chemical suits kitchen oil fires, and lithium-ion extinguishers suit battery areas. See Fire Extinguishers.
Are your fire extinguishers ISI-marked?
Yes. All extinguishers we supply are ISI-marked. Our own CEASE FIRE range, from 1 kg to 150 kg trolley units, is designed to IS 15683.
Can I use water on an electrical or oil fire?
No. Water can cause electric shock on an electrical fire and can spread an oil fire. Use a CO2 or ABC extinguisher on electrical fires and a K-class extinguisher or fire blanket on cooking oil.
Working with Cease Fire
Which areas do you cover?
Mumbai, Thane, Navi Mumbai and the rest of Maharashtra, and projects across India.
Is the site survey free?
Yes. We inspect your building or review your drawings before quoting.
How do I get a quote?
Send your requirement, drawings or BOQ to sales@ceasefireservices.com, call +91 9920676281, or use the enquiry form.
What licences do you hold?
We are a Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95), a licensed Fire and Life Safety Auditor (MF&ES/F&LSA/30052026/011) and hold Maharashtra Electrical Contractor Licence No. 17545. See Standards & Certifications.
Can you work in an occupied building?
Yes. We plan work with building management so occupied areas stay protected during installation and upgrades.
Didn't find your answer?
Send your question to our team, or read our Fire Safety Guides and Blog.