Engineer turning the valve on a red wet-riser pipe beside an open hose cabinet in a stairwell

Fire Hydrant System Installation in Mumbai

Cease Fire & Electrical Services LLP provides fire hydrant system installation in Mumbai, from design and the pump room to wet risers, hose reels, yard hydrants and the fire brigade inlet. We are a Maharashtra Fire Services Licensed Agency and have delivered fire protection projects for housing societies, commercial buildings, factories and government sites since 1992. After testing, we issue Form A and can maintain the system under AMC.

What is a fire hydrant system?

A fire hydrant system is a network of fixed pipes kept full of water under pressure by dedicated fire pumps, with outlets where hoses are connected to fight a fire. Inside a building, the vertical pipe is called a wet riser, with a landing valve, hose box and hose reel on each floor. Outside, yard hydrants sit on a ring main around the buildings. The system gives trained staff and the fire brigade a reliable water supply from the first minutes of a fire.

Where hydrant systems are needed

  • Engineer checking a hose reel cabinet in the lift lobby of a residential tower

    Residential towers and housing societies

    Wet riser with landing valves, hose boxes and hose reels on each floor, terrace booster pump, fire brigade inlet

  • Engineer looking up at a ceiling smoke detector on an open-plan office floor, a call point and extinguisher on the column beside him

    Commercial buildings and offices

    Wet riser and hose reels, pump room shared with the sprinkler system

  • Two engineers walking a factory production floor past a red hydrant post and hose reel cabinet

    Factories and warehouses

    Yard hydrant ring main around the buildings, internal hydrants and hose reels, pump room sized for the site

  • Engineer testing a ceiling smoke detector with a pole tester in a hospital corridor

    Hospitals, hotels and schools

    Wet riser and hose reels on every floor, linked to sprinklers and fire alarms

  • Engineer testing a fire alarm call point in a school corridor

    Government and institutional campuses

    Complete fire fighting systems for hostels, offices and public buildings

The systems a building needs depend on its height, use and floor area under the National Building Code of India (NBC) and the fire brigade's requirements. We confirm this during the free site survey.

Components of a fire hydrant system

We supply the hydrant valves, hoses, hose reels, hose boxes, fire pumps and valves ourselves. UL listed and FM approved pumps and valves are available where your consultant or insurer needs them.

Design standards

We design hydrant systems to the NBC and NFPA standards, and to UL/FM requirements where the project calls for them. Our MEP engineers prepare the layout and drawings, and we check pipe sizes and pump duty with hydraulic calculations before anything is installed.

Hydrant valves, hose, couplings and branch pipes we supply are made to Indian Standards: IS 5290 (Type A and Type B landing valves), IS 636 (RRL hose), IS 903 (couplings and branch pipes) and IS 884 (hose reels), from SANT and other makers.

Our process

  1. Free site survey

    We visit the site, study the building and any existing system, and confirm what the fire brigade will expect.

  2. Design

    Layout, pump sizing, hydraulic calculations and drawings.

  3. Supply and installation

    Pump room, pipework, risers, valves, hose boxes and hose reels, installed by our own team.

  4. Testing and commissioning

    Pressure testing of the pipework, pump performance and flow at the outlets, and a demonstration and training for your staff.

  5. Form A

    As a licensed agency, we issue the Form A certificate for the work we have done, which you submit to the fire brigade.

  6. AMC and Form B

    Planned maintenance, usually quarterly checks with an annual service, and the Form B certificate each January and July.

Continuous monitoring of the hydrant system

In Maharashtra, covered buildings must now have an Automated Continuous Monitoring System (ACMS) under the fire rules amendment of 12 June 2025. We connect the hydrant pump room to our FireSense IoT panel, which reports the status of the main, jockey and diesel pumps, the diesel tank level, pump power and the fire water tank every minute. The owner and the licensed agency are alerted when something fails, so a flat battery or a stopped jockey pump is found before it matters. Read our guide to ACMS, Form A-1 and Form B-1, or see FireSense IoT monitoring.

Hydrant projects

  • Engineer crouching at a red yard fire hydrant, reading a pressure gauge, a fire brigade inlet on the wall beside it

    LBS IMU Mumbai Port Campus (CPWD), Sewri

    Fire fighting and sprinkler systems for a G + 11 hostel.

  • Engineer in a hard hat drawing the nozzle from a red hose reel in an open wall cabinet

    Palkhi Roha, Kandivali East (G + 14)

    Fire fighting, sprinkler, fire detection and signage systems, completed in April 2024.

  • Engineer reading the pressure gauge on a red riser valve above a four-way fire brigade inlet, at the entrance of a residential tower with a slatted, planted podium

    Palkhi MRDA, Kandivali (G + podium + 13), for KCD Realty

    Fire fighting, sprinkler, fire detection and signage systems.

See all projects and case studies

Maintenance and Form B

A hydrant system only works if it is maintained. On each service visit we check the main, jockey, diesel and booster pumps, the pump control panel and pressure gauges, every hydrant valve, coupling, hose, hose reel, nozzle, hose box and branch pipe, the yard hydrants and the fire brigade inlet. Under the Maharashtra Fire Prevention and Life Safety Measures Act, 2006, building owners must submit a Form B certificate from a licensed agency every January and July. We can include it in your AMC.

Why choose Cease Fire

  • Since 1992

    1,500+ projects and the Rashtriya Nirman Ratna Award for Best Government Contractor (2002).

  • Licensed

    Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95), so we issue Form A and Form B ourselves.

  • Design in-house

    Our MEP team designs the system and runs the hydraulic calculations.

  • One team

    Pump room, pipework, products, testing and AMC from one company.

  • Government work

    CPWD enlisted, with projects such as the LBS IMU hostel in Sewri.

Book a free site survey

We work across Mumbai, Thane, Navi Mumbai and Maharashtra, and take on projects across India. Tell us your building type, number of floors and location, and send drawings if you have them. We will visit, confirm what the fire brigade needs and send a clear proposal.

Frequently asked questions

What is a fire hydrant system?

A fire hydrant system is a network of pipes kept full of water under pressure by fire pumps, with hydrant valves where fire hoses are connected. It gives a reliable water supply for fighting a fire inside and around a building.

What are the main parts of a fire hydrant system?

The main parts are the fire water tank, the main, jockey and diesel fire pumps, the pump control panel, the wet riser or ring main, hydrant valves, hoses, hose reels, hose boxes and the fire brigade inlet.

What is the difference between a wet riser and a yard hydrant?

A wet riser is a vertical pipe inside a building with a hydrant valve on each floor. Yard hydrants are outlets on a pipe ring main laid around the outside of the buildings, common in factories and large campuses.

Which buildings need a fire hydrant system?

It depends on the building's height, use and floor area under the National Building Code and the fire brigade's requirements. We confirm exactly what your building needs during a free site survey.

Does Cease Fire provide Form A after installing a hydrant system?

Yes. As a Maharashtra Fire Services Licensed Agency, we issue Form A for the work we complete, which you submit to the fire brigade.

How often should a fire hydrant system be serviced?

Most sites have quarterly checks and an annual service under AMC. A licensed agency must also inspect the system and issue Form B every January and July.

Can you upgrade or repair an existing hydrant system?

Yes. We review the existing system, list what needs rectifying or replacing, and carry out the work with the right documentation.

How much does a fire hydrant system cost?

The cost depends on the building size, pump capacity, length of pipework and number of outlets. We give a written quote after a free site survey or from your drawings.

Can a hydrant system be monitored remotely?

Yes. Our FireSense IoT panel reports pump status, diesel tank level, pump power and tank levels, and supports the ACMS now required for covered buildings in Maharashtra. Alerts go to the owner and to us as the licensed agency.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.