
Sprinkler Hydraulic Calculations with SprinkCALC and PIPENET
Cease Fire & Electrical Services LLP prepares hydraulic calculations for sprinkler and hydrant systems using SprinkCALC and PIPENET software. We size pipes, check pressures and flows at the most demanding areas, and confirm the pump duty your system needs. You receive a calculation report your consultant, contractor or fire authority submission can use. We are based in Mumbai and have worked on fire protection since 1992.
What we calculate
- Sprinkler hydraulic calculation (SprinkCALC)
- Flow and pressure at the most remote design area, and the pipe sizes needed to deliver them
- Hydrant and ring main network (PIPENET)
- Flow and pressure at each hydrant and landing valve across the network
- Water curtain, deluge and spray networks (PIPENET)
- Flow and pressure at each nozzle, to confirm even coverage
- Fire pump duty
- The flow and head the fire pump must deliver, from the worst-case calculation
- Pipe sizing and optimisation
- Where pipe sizes can be reduced safely or must be increased
- Existing system check
- Whether an existing network can support a fit-out, extension or change of hazard
Why hydraulic calculations matter
Right-sized pipes and pumps
Avoid under-performing systems and oversized, costly pipework.
Design basis on record
Calculations show how the system was designed, for consultants, insurers and reviewers.
Changes checked before they're built
Fit-outs and extensions can reduce the pressure available at existing sprinklers. A calculation shows this in advance.
Who uses our calculation service
- MEP consultants who need calculations for their fire protection design.
- Fire protection contractors preparing shop drawings and pump selections.
- Developers and architects who need the design basis for a new building.
- Facility teams planning a fit-out or change of use in an existing building.
How it works
Share drawings
Sprinkler and hydrant layouts, building use and water supply details.
Agree the basis
Hazard class, design standard, design area and the outputs required.
Model and calculate
We build the network in SprinkCALC or PIPENET and run the calculations.
Review results
We flag any low pressures or undersized pipes and suggest changes.
Issue the report
Calculation summary, software output and node diagrams.
Why choose Cease Fire
Design and site experience
1,500+ fire protection projects installed and maintained since 1992, including FM-guideline roof sprinklers with seismic bracing for Roquette India's warehouses.
Licensed
Maharashtra Fire Services Licensed Agency (MFS/
LA/ ). See our certifications.RF-93/ RD-95 Full design support
Calculations can be part of complete fire and plumbing design.
Send your drawings for a quote
Share your sprinkler or hydrant layouts and building details. We'll confirm the calculation scope and send a proposal.
Frequently asked questions
What is a sprinkler hydraulic calculation?
It is an engineering calculation that checks whether a sprinkler system can deliver the required water flow and pressure at the most demanding area. It is used to size pipes and select the fire pump.
What is the difference between SprinkCALC and PIPENET?
SprinkCALC is used mainly for sprinkler system calculations. PIPENET is used for larger pipe networks, such as hydrant ring mains and spray systems. We choose the right tool for your system.
Can you calculate water curtain and deluge systems?
Yes. Spray, deluge and water curtain networks can be modelled in PIPENET to check flow and pressure at each nozzle. We need the nozzle layout and supply details.
What information do you need?
Sprinkler and hydrant layout drawings, building use and hazard class, pipe material, and water supply or pump details.
Which standards do you calculate to?
The standard agreed for your project, such as NFPA 13, NBC 2016, FM/UL, EN/VdS or IS standards, as required by your consultant, insurer or authority.
Can you check an existing sprinkler system?
Yes. We can model an existing network to check whether it can support a fit-out, extension or change of use.
Will the calculation guarantee our fire NOC?
No. The calculation documents the design basis. The fire brigade issues the NOC after its own review and inspection.
How long do calculations take?
It depends on the size and number of design areas. We'll confirm the timeline in the proposal after seeing your drawings.
How do we get a quote?
Email your drawings to sales@ceasefireservices.com, call +91 9920676281 or use the enquiry form.
Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.
Call +91 9920676281







