Non Return Valve (NRV) for Fire Pump Lines in Mumbai

A red flanged swing check valve beside a wafer dual-plate check valve

Cease Fire & Electrical Services LLP supplies the non return valve (NRV) for fire pump, hydrant and sprinkler lines in Mumbai, in 40 mm to 300 mm sizes rated PN 1.6, 2.0 and 2.5 MPa. An NRV lets water flow one way and closes by itself when flow reverses, so it protects pumps that are not running and holds pressure in the system. We supply cast iron swing type (reflux) valves, dual plate check valves and wafer check valves, and install them as part of pump room and hydrant work.

Types we supply

TypeSizesConstructionEndsTest and rating
Swing type (reflux valve)50 to 300 mmCast iron body, cover and hinge (IS 210 FG 200); bronze seat ring; cast iron disc with rubber face ring; stainless steel hinge pinFlanged to IS 1538 or Class 150; made to IS 5312 Part 1Body 2.4 MPa, seat 1.6 MPa; PN 1.6, 2.0, 2.5 MPa
Dual plate check valve50 to 300 mmCast iron body; SG iron or stainless steel plates; SS 304 spring; SS 410 pinWafer, fitted between flangesShell 24 kg/cm², seat 16 kg/cm²; PN 1.6, 2.0, 2.5 MPa
Wafer check valve40 to 300 mmDuctile iron body; SG iron disc; EPDM liningWafer, fitted between flanges1.6, 2.0 and 2.5 MPa

For small screwed lines we also supply bronze swing check valves (15 to 100 mm) and forged brass multi-utility check valves (15 to 50 mm).

Where NRVs go in a fire system

  • Fire pump delivery: one NRV on each pump, between the pump and its delivery isolation valve, so water from running pumps cannot flow back through an idle one.
  • Jockey pump delivery: keeps system pressure from pushing back into the jockey pump when it stops.
  • Fire brigade inlet: stops system water flowing out through the inlet when it is not in use.

Which type to choose

  • Swing type: simple and robust, with low pressure loss when open. It needs more length in the line and suits horizontal pipes or vertical pipes with upward flow.
  • Dual plate: a short, light wafer body with two spring-loaded plates that close quickly, which helps limit slamming when a pump stops.
  • Wafer check: a compact single-disc valve for tight spaces.
  • We confirm the type against the pump room layout and your consultant's specification.

Supply, installation and servicing

We supply NRVs on their own or with the pumps, isolation valves and headers of a pump room. On our projects we fit them in the right direction of flow and test them with the system. During AMC visits we check that each NRV closes properly when its pump stops, and we replace valves that leak back or slam.

Engineer turning the hand wheel of a red gate valve on pump room pipework, with a butterfly valve, a non-return valve and a strainer along the same pipe

Why choose Cease Fire

  • Since 1992

    A Maharashtra Fire Services Licensed Agency (MFS/LA/RF-93/RD-95) with 1,500+ projects.

  • Pump room knowledge

    We install and maintain fire pumps, so we fit each NRV where it protects the pump.

  • One supplier

    Valves, fire pumps, hydrant accessories and installation from one team.

Request a valve quote

Send your BOQ or valve list with type, sizes, pressure rating and quantity. We will confirm the specification and quote.

Frequently asked questions

What does a non return valve do in a fire pump line?

It lets water flow out of the pump into the system but stops it flowing back. This protects pumps that are not running and holds pressure in the pipework.

Where is the NRV fitted on a fire pump?

On the delivery side, between the pump and the delivery isolation valve. Each fire pump and the jockey pump has its own NRV.

What is a reflux valve?

It is another name for a swing type non return valve. Our cast iron reflux valves are made to IS 5312 Part 1 with flanged ends.

What is the difference between a swing type NRV and a dual plate check valve?

A swing type NRV has a single hinged disc in a longer flanged body. A dual plate check valve uses two spring-loaded plates in a short wafer body, so it takes less space and closes faster.

What sizes and pressure ratings do you supply?

Swing type and dual plate valves come in 50 mm to 300 mm, and wafer check valves in 40 mm to 300 mm. All are rated PN 1.6, 2.0 and 2.5 MPa.

How do I know if an NRV has failed?

Common signs are a pump spinning backwards after it stops, the jockey pump starting too often, or pressure dropping when the pumps stop. We check NRVs during AMC visits and replace faulty ones.

Can you supply UL listed or FM approved check valves?

Yes. UL listed and FM approved valves are available. Tell us what your consultant or insurer specifies, and we will share the manufacturer's certificate for the exact model with our quote.

Can a failing NRV be spotted remotely?

FireSense IoT monitoring reports riser pressure and pump status every minute, so pressure that falls after the pumps stop shows up in the data. It supports the ACMS required for covered buildings in Maharashtra.

Question not answered here? Call our team, Monday to Saturday, 9 am to 7 pm.

Call +91 9920676281